Fault self-inspection

CARER

The oxygen concentrator is running normally, but oxygen is not coming out of the oxygen outlet?

1. Check whether the oxygen flow rate is at 0, if it is at 0 again, you need to re-adjust the flow to the normal flow range.
2. Remove the humidification bottle and re-tighten the cap. When oxygen passes through the humidification bottle, if the bottle cap is not tightened tightly, it is easy to leak air, resulting in no oxygen coming out of the oxygen outlet.
CARER

Why is the machine powered on but not running?

1. Check whether the power supply is loose or falling off. If it is loose or falls off, you need to contact maintenance.
2. Check whether the power overload protector on the back of the machine has bounced off. If it bounces off, you need to push the protector again to the normal position.
3. It may be an internal failure of the machine, and the machine needs to be sent to a maintenance center for testing.
CARER

What is the reason for the drops of water in the oxygen suction tube?

Condensed water caused by temperature difference between room temperature and water temperature in the humidification bottle, solution:
1. When using a long oxygen suction tube, do not let the oxygen suction tube touch the ground.
2. The temperature in the control room should not be lower than 20 degrees Celsius.
3. Increase the flow rate of the oxygen generator to more than 3L.
4. Put less water in the humidification bottle, and the water can touch the oxygen outlet pipe in the cup.
5. Wrap the humidification cup with a towel.
6. The water poured into the humidification cup needs to be stored in a room with a higher room temperature (in the bedroom).
7. Use the water collector to temporarily store water droplets and play a blocking role.
8. Regularly clean the nasal suction tube according to the frequency of use: turn on the flow rate of the oxygen generator to the maximum, without connecting the humidification bottle, and dry the water against the nasal suction tube (it is recommended to replace the oxygen suction tube every 1-2 months).
CARER

What is the reason for the peculiar smell of oxygen coming out of the machine?

Oxygen is colorless and odorless, and the smell comes from the epoxy sterilization of new oxygen inhalation tubes and masks. It is recommended to use an oxygen generator to frequently open windows for ventilation. The smell will dissipate in about 1-2 weeks.
CARER

How often should the filter cotton and air intake filter of the oxygen generator be replaced?

1. The filter cotton should be washed and dried every week for repeated use. It is recommended to replace it with a new one every six months.
2. Replace a new air intake filter every 1000 hours of accumulated use time.
CARER

How to eliminate the alarm prompt for the replacement of the intake filter of the oxygen generator?

You need to press the voice + atomization button at the same time for more than 3 seconds to eliminate it.
CARER

Why is the timer not accumulating time?

Oxygen generators will only accumulate if they are used for more than 1 hour each time.
CARER

When using the atomization mode, the oxygen outlet and the atomization port output gas at the same time, is it normal?

is normal. Oxygen is produced when the machine is powered on. It's just that in the oxygen generation mode, the atomization port is blocked. In atomization mode, the oxygen outlet does not need to be blocked. In the atomization mode, the oxygen concentration will decrease, and there will be a small amount of outgassing, which is a normal phenomenon.

After-sales scope

Warranty scope

The following consumables: air intake filter, air intake filter cotton, humidification bottle and random gifts and other consumables are not covered by the warranty

Not covered by warranty

1. Misuse causes damage to the product

2. Damage caused by unauthorized disassembly or modification of any part of this product

3. Failure to follow the precautions in the manual causes damage to the product

4. Use of abnormal voltage or damage to the product due to accidents (such as fire, flood, etc.) and any other force majeure factors

5. No warranty certificate or altered warranty certificate

6. The product has passed the warranty period

Warranty time

From the date of purchase, the whole machine is guaranteed for one year. If it is not used normally according to the precautions, the damage caused by man-made products beyond the warranty period will be repaired for a fee. For warranty or maintenance, please contact the dealer where you purchased the product. Please show the warranty certificate when repairing. If you need to charge, the service personnel will explain to you the composition of the charge, and the repair will only be charged after obtaining your consent.

In order to avoid accidental loss, please repair the oxygen generator at the dealer or maintenance point authorized by Keer.

Fault self-inspection

CARER

When the "power switch" is turned on and the "on/off" button is pressed, the oxygen generator does not run, the power indicator light is off, the alarm sounds and the maintenance light flashes. What is the reason and how to deal with it?

1. The power cord is not inserted into the power socket correctly. Check the connection between the power cord and the power socket, and the power system should be consistent with the specifications on the nameplate.
2. There is no electricity in the power socket. Check the disconnect switch in your home and restart if necessary. If the same problem recurs please use another outlet.
If it still does not work after the above methods, please contact your dealer.
3. The "overload protector" of the oxygen generator is disconnected. If the overload protector trips, please contact your dealer.
CARER

When the switch is turned on, the oxygen generator is running, the power indicator light is on, the red maintenance indicator light is on, and the alarm may be heard. What is the reason and how to deal with it?

1. The intake filter cotton is blocked. Check the air intake filter cotton, if it is clogged, it needs to be cleaned.
2. The exhaust device is blocked. Check the exhaust port to make sure the exhaust port of the oxygen generator is not blocked.
3. The air intake filter cloth is blocked, check the air intake filter cloth, if it is blocked, it needs to be replaced.
4. The nasal oxygen tube or mask is blocked. Disconnect the nasal oxygen tube from the oxygen outlet. If the flow rate rises, check whether the nasal oxygen tube is blocked. If necessary, replace the nasal oxygen tube or mask.
CARER

When the switch is turned on, the oxygen generator runs, the power indicator light is on, and a low-frequency vibration can be heard.

The solenoid valve is not functioning properly, turn off the oxygen concentrator immediately, switch to your alternate oxygen source, and contact your dealer.

After-sales scope

Warranty scope

The following consumables: intake filter cloth, intake filter cotton, humidification bottle and random gifts and other consumables are not covered by the warranty

Not covered by warranty

1. Misuse causes damage to the product

2. Damage caused by unauthorized disassembly or modification of any part of this product

3. Failure to follow the precautions in the manual causes damage to the product

4. Use of abnormal voltage or damage to the product due to accidents (such as fire, flood, etc.) and any other force majeure factors

5. No warranty certificate or altered warranty certificate

6. The product has passed the warranty period

Warranty time

From the date of purchase, the whole machine is guaranteed for one year. If it is not used normally according to the precautions, the damage caused by man-made products beyond the warranty period will be repaired for a fee. For warranty or maintenance, please contact the dealer where you purchased the product. Please show the warranty certificate when repairing. If you need to charge, the service personnel will explain to you the composition of the charge, and the repair will only be charged after obtaining your consent.

In order to avoid accidental loss, please repair the oxygen generator at the dealer or maintenance point authorized by Keer

Fault self-inspection

CARER

What should I do if there is no pressure after the product is powered on, or if the pressure is not enough?

Check whether the power supply voltage meets the requirements.

After-sales scope

Warranty time

From the date of purchase, the whole machine is guaranteed for one year.

If it is not used normally according to the precautions, it will be damaged by man-made or it will be repaired for a fee if it exceeds the warranty period. For warranty or maintenance, please contact Kohl authorized dealers. Please show the warranty certificate when repairing. If you need to charge, the service personnel will explain to you the composition of the charge, and the repair will only be carried out after obtaining your consent.

Fault self-inspection

CARER

What are the causes of mask leakage and how to deal with them?

1. If the mask is not worn properly, re-wear the pipeline.
2. The pipe falls off, reconnect the pipe.
3. Internal air leakage, contact nurses or service personnel.
4. The humidification cup is not assembled in place, reinstall the humidification cup.

After-sales scope

Warranty scope

Humidifier 90 days, power adapter 1 year, main unit 2 years

Not covered by warranty

1. Failure caused by unauthorized disassembly and modification of the product;

2. Faults caused by accidental drop during use and handling;

3. Faults caused by lack of reasonable maintenance;

4. Faults caused by failure to operate in accordance with the correct instructions in the instruction manual;

5. Failures caused by improper repairs by repair shops not authorized by the company;

6. Any damage caused by splashing water on or inside the electronic device.

Fault self-inspection

CARER

What is the reason for the incomplete LED display?

Maybe the LED frame is not pressed tightly and the LED needs to be replaced.

After-sales scope

Warranty time

From the date of purchase, the product can enjoy a one-year free warranty and lifetime maintenance with the purchase invoice.

We will not provide free warranty service for the following faults caused by the user

1. Failure caused by unauthorized modification or disassembly of the product

2. Faults caused by accidental drop during use and handling

3. Faults caused by lack of reasonable maintenance

4. Faults caused by failure to follow the correct instructions in the instruction manual

When requesting free warranty service, you must have the warranty card with the date of purchase and the seal of the shop where you purchased it. Please be sure to ask the shop assistant to stamp the warranty card when purchasing this product. When requesting free warranty service, please take this product to a repair shop"

Fault self-inspection

CARER

Display the reasons for low battery power, and how to deal with it?

The battery power is low, or the battery is placed in an incorrect position. Replace the battery with a new one, and insert it into the correct position again according to the direction of the battery (+) and (-) poles.

After-sales scope

Warranty scope

From the date of sale of this product, if there is a quality problem caused by non-human factors within one week, the company is responsible for refund, replacement, and warranty; under normal use and storage, if this product has quality problems within three years, the user will Shopping invoices and warranty cards are given free maintenance, except for consumable and vulnerable parts (including bladders, air pipes, air connectors, buttons, panels, batteries). Services beyond three years will be charged reasonably.

Free maintenance services will not be provided for the following faults or damages caused by the user's personal reasons

1. Faults caused by unauthorized disassembly, repair and modification of this product

2. Faults caused by incorrect operation

3. Damage caused by accidental drop

4. Faults caused by unreasonable maintenance

5. Corrosion damage caused by battery leakage

6. Faults caused by improper repairs at non-Hetai authorized maintenance points, etc.

When performing warranty service, if you need to provide circuit diagrams, necessary materials, and any problems with the maintenance of electrical circuits, please contact the manufacturer.

Fault self-inspection

CARER

Why is the product not displayed?

1. The pulse oximeter will automatically shut down after 8s if no signal is detected, which is a normal phenomenon.
2. The battery may be low, please replace the battery.
CARER

The product cannot be turned on, what is the reason?

1. The battery may be low or dead, please replace the battery.
2. The battery may not be installed correctly, please reinstall the battery.
3. The instrument may be damaged, please contact the customer service center of the company.
CARER

What causes pulse oximetry or pulse rate to show instability?

1. The finger may not be inserted deep enough, please insert the finger correctly and try again.
2. If your fingers are shaking or your body is in motion, please try not to move.

After-sales scope

Warranty scope

Only users who purchase products from our company or our authorized dealers can enjoy the warranty service. Warranty service is applicable to products that have malfunctioned under normal use by the user within the specified warranty period. In order to relieve your worries about the purchase of the machine, Hexin Zhongdian Company makes the following warranty commitments for you, and provides services to you accordingly:

1. From the date of purchase, the product will be refunded within 7 days, replaced within 15 days, guaranteed for one year, and maintained for life.

2. Please keep this warranty card properly.

Disclaimer

In any of the following situations, there is no warranty:

1. Periodic inspection, maintenance, repair or replacement of parts due to normal wear and tear.

2. Damage caused by falling, extrusion, water immersion, damp and other man-made damages.

3. Damage caused by natural disasters such as floods, fires, and lightning strikes.

4. Product failures caused by failure to follow the maintenance instructions in the product manual and irregular operations.

5. Machines repaired by non-authorized repair organizations

6. Consumables are not covered by the warranty.

After-sales scope

Warranty scope 

If there are any quality problems (excluding those caused by human factors) within one month from the date of purchase, under the conditions of proper storage and normal use, the product can be returned and repaired free of charge. 

Natural wear shall not be included in the warranty.